Axis of control: 1.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
7 operating modules required for easy positioning control are provided.
Type of instruction, please refer to the list in front of you.
One can control a shaft FR-F820-00167-2-60.
FX3U, PLC FX2N can connect up to 88 units,
PLC FX2NC can connect up to 4 units,
PLC FX3UC can connect up to 7 units, so that it can control more than one independent axis.
Maximum can output 100kHz pulse train FR-F820-00167-2-60.
Positioning control through the control program. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 18.5kw.
SLD converter rated current: 47A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have FR-F820-00167-2-60.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption MITSUBISHI FR-F820-00167-2-60.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program MITSUBISHI FR-F820-00167-2-60.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements MITSUBISHI FR-F820-00167-2-60.
The control of each machine can be done separately by the frequency converter, and the control of the dispersion is also carried out.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "
MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station.
BBuilt in 2 PID arithmetic FR-F820-00167-2-60. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced.