Specifications: FX0N-30EC.
Cable extending unit.
Length 30CM. Total input and output points: 16 points.
Output points: 16 points.
Output type: transistor output.
FX Series in the compact body built in superior performance, and strive to operate simple.
In addition, rich options can meet the various needs of customers FX2N-64MT-ES/UL.
In thee virtual factory will be rich in the function of a part of the introduction.
It is easy to control the analog quantity of the application.
Can be extended to all models in the FX series analog devices FX2N-64MT-ES/UL.
Function extension board, special adapter without programming can be used for communication.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect FX2N-64MT-ES/UL.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit MITSUBISHI FX2N-64MT-ES/UL.
Max input / output points: 64 points.
Supply voltage: 100 - 240VAC.
Input points: 32 points.
Output points: 32 points.
Output type: transistor.
Power consumption: 60VA.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87 MITSUBISHI FX2N-64MT-ES/UL.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program MITSUBISHI FX2N-64MT-ES/UL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). The terminal row is converted to e-CON.Input points: 16 points.
Output points: 16 points.
Output form: transistor.
Connected programmable logic conttroller: FX1NC, FX2NC, FX3UC FX2N-64MT-ES/UL.
FX2NC expansion module can be directly connected to the FX1NC, FX2NC, PLC FX3UC on the expansion of the input and output.
Do not need to connect the cable and so on, therefore can carry on the compact expansion.