Control output: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnot: Detection for Single-phase heater.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series G2R-1-S AC100.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track
G2R-1-S AC100
Removable terminal block for easy replacement to simplify maintenance.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications G2R-1-S AC100.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions .
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel. Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input G2R-1-S AC100.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurableAppearance: Rectangular (M16-T).
Lighting: LED without Voltage Reduction Unit, 24 VAC/VDC.
Degree of protection: IP65 oil-resistant.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternaate,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV G2R-1-S AC100.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs G2R-1-S AC100.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
G2R-1-S AC100 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G2R-1-S AC100&select=5