Appearance: L-shaped.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection .
Protective circuit for safe operation K2CM-1H.
A built-in connector minimizes the shape and dimensional,
requirements
K2CM-1H
Two outputs: light-ON and dark-ON.
Complete lineup including seven different shapes.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending) K2CM-1H.
The indicator can be seen from many directions to enable,
installation in more locations .
Connector with lock that mates with commercially available,
connectors. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling K2CM-1H.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: M12 connector.
Body material: Stainless steel.
Thread length (ooverall length): 27 (43) K2CM-1H.
Ouutput configuration: PNP .
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpiecees are eliminated K2CM-1H.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization.
K2CM-1H Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=K2CM-1H&select=5