Power supply voltage: 24 VDC.
Output: Relay.
Timer function: Yes.
Features: Multi-function with two inputs/one output.
Offers High-speed Input Response of,
0.1 ms and Equipped with Built-in Timer,
High-speed response of 0.1 ms.
Ideal as a two-input Controller.
Lineup includes the S3D2-BK with flip-flop functions convenient for,
level control, the S3D2-AKD/CKD/CCD with 24-V power supply, and,
the S3D2-DK/EK with one input/output OFF-delay (two circuits),
useful for load control and lamp display,
Power source for the Sensor can be supplied up to 200 mA
LAB1N DC5
Ultra-slim body with 30-mm width.
Multi-function model equipped with timer functions also available LAB1N DC5. Appearance: Round/Full-guard type A22-G .
Output: SPST-NO + SPST-NO.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks LAB1N DC5.
Finger protection mechanism on Switch Unit provided as a standard feature .
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Terminal: Solder terminal.
Actuator: Short spring plunger.
Direct Current Switch with.
Built-in Magnetic Blowout.
Incorporates a small permanent magnet in the contact.
mechanism to deflect the arc to effectively extinguish it.
Same shape and mounting procedures as the Z Basic Switches. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points.
Communication: -.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Reemote SP input function, suupport for a variety of applications LAB1N DC5.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) LAB1N DC5.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
LAB1N DC5 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=LAB1N DC5&select=5