Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns MM4XP-D DC24.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
MM4XP-D DC24
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection MM4XP-D DC24. Unit classifi cation: CS1 CPU Bus Unit .
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring GI cabl;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units) MM4XP-D DC24.
No. of unit numbers allocated: 1 .
Current consumption: 5V, 0.65A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Large Setting Dial and Moving Pointers Ideal,
for Easy Operation and Monitoring.
Incorporating an easy-to-see large setting dial with moving pointers.
Wide time-setting range of 0.2 s to 60 h.
(available through three time-range model types).
Wide AC power supply range (100 to 240 VAC).
IP65 watertight and dust-tight front panel.
Approved by UL and CSA.
Conforms to EN61812-11 and IEC60664-1 MM4XP-D DC24.
4 kV for Low Voltage, and EMC Directives .
Conforms to EMC standards.
Six-language instruction manual provided.
Programmable contact enables the building of a self-holding,
relay circuit as well as built-in instantaneous contact. (-NS).
Memory reteenttion (-NSR) MM4XP-D DC24.
Finger protection terminal block.
Enables easy sequence checks through instantaneous outputs.
for a zero set value at any time range.
MM4XP-D DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MM4XP-D DC24&select=5