Name: CJ1 Special I/O Unit.
Specifications: Type of communications,
Remote I/O communications, Message communications;
Maximum number of I/O points per Master Unit,
Word Slave Units: 1,024 inputs and 1,024 outputs,
(2,048 I/O points total)Bit Slave Units:
256 inputs and 256 outputs (512 I/O points total) .
No. of unit numbers allocated: 1, 2, 4, or 8 MY4J AC100/110.
Current consumption : 5V, 0.4A; 24V,--
MY4J AC100/110
Standards: CE, U, U1, L, N.
NJ/CJ-series CompoNet Master Units Increase,
the Range of Applicability of Sensors and Actuators.
The NJ/CJ-series CompoNet Master Unit manages,
the CompoNet network, controls communications,
between the Controller and Slave Units,
and handles I/O data and message data MY4J AC100/110. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use MY4J AC100/110.
Event input points: -.
Transfer output: output (using control output) .
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through thhe support software (VVer MY4J AC100/110.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication MY4J AC100/110.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.