Actuator: Roller lever R38.
Item: Hermetic seal, Molded terminals, -139 models, Basic.
Pretravel (PT): 15±5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches A22E-M-02.
Standard-feature gold-clad crossbar contacts provide high reliability
A22E-M-02
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models A22E-M-02. Terminal type: Enclosed-terminal Models.
Protective tubing length L: 50cm.
Protective tubing diameter D (mm): 8 dia.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers A22E-M-02.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal . E3Z-T67-G0 detection methods: the firing pattern.
Connection: socket type (M8).
Detection range: 30m.
Output mode: NPN output.
Achieve small, long distance, save electricity and
Standard type of photoelectric sensor for energy saving
Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically altternate,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV A22E-M-02.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs A22E-M-02.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
A22E-M-02 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22E-M-02&select=5