Control power supply voltage: 100/110 VAC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) C1000HF-CPUA1-V1.
Detect three-phase AC current for under and/or overcur,
rent using current converter
C1000HF-CPUA1-V1
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection C1000HF-CPUA1-V1.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) .
LED operation indicator.
UL/CSA approval (SDV-F@). Models: 3 UVR (27).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular C1000HF-CPUA1-V1.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring. Appearance: Knob-type Selector Switch A22W,
LED lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Manual.
Output: SPST-NC + SPST-NC.
Operating voltage: 6 VAC/VDC.
Illumination color: R (red); Y (yeellow); G (green); AA (blue) C1000HF-CPUA1-V1.
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounttedd using either open-type (fork-type) or closed-type,
(round-type) crimp terminals C1000HF-CPUA1-V1.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
C1000HF-CPUA1-V1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=C1000HF-CPUA1-V1&select=5