Actuator: Fork lever lock (left operation).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available C500F-CPUA1-V1. )
M12-connector models are also available, saving on labor and,
simplifying replacement
C500F-CPUA1-V1
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC C500F-CPUA1-V1.
Type: Welding / wire type, M3 screw mounting .
Drive rod: leaf Shibai rod type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1 C500F-CPUA1-V1. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Item: Operation indicator (LED) *1; High-sensitivity 10°.
Actuator: Roller lever, pre-wired connector *3; 4 conductors; DC.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV statte display function, tto see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV C500F-CPUA1-V1.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm fflexible contact output C500F-CPUA1-V1.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
C500F-CPUA1-V1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=C500F-CPUA1-V1&select=5