Sensing method: Through beam (with slot).
Sensing distance: 5 mm (slot width).
Output configuration: Light-ON Dark-ON (2 outputs).
Connection method (Cable length): Pre-wired model with robot cable (1 m).
Output type: NPN.
Meeting Customer Needs with.
Ultra-compact Sensors that Mount.
with M3 Screws .
Mount using M3 or M2 screws.
Reliable sensing slot depth of 6 CV500-CN525. 5 mm.
Indication of sensing window for easy confirmation of,
insertion depth
CV500-CN525
Bright indicator for confirmation from many directions.
Both light-ON and dark-ON outputs provided.
All models available with either standard cable or,
flexible robot cable.
Load short-circuit protection circuit provided CV500-CN525. Name: Two-tier Screw Terminal Block .
Specifications: Outputs; 8 outputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CV500-CN525.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Classification: Momentary operation.
Shape of Operation Unit: 36 dia. 25 dia.
Output: 2.
Operation Unit color: Green (-G).
Long Service Life with Built-in Z-series.
Basic Switch.
Using a Basic Switch enables direct switching of large-capacity loads.
Shock-absorbing construction of Operation Unit protects the Switch.
Drip-proof Pushbutton construction enables use in locations subject to,
splashing water and oil and scattering dust.
Pushbuttons are available in three shapes and six colors. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 15 W.
Output voltage: 24 V.
Output current: 0.65 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 3000-/600-W models) CV500-CN525.
Safetty standards: UL 508/60950-1, cUL CSA C22 .2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply CV500-CN525. ).
CV500-CN525 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=CV500-CN525&select=5