Cable length: 30 meters.
FXCPU GOT.
FXCPU communication function expansion board GOT.
[MINI-DIN 8 pin loose line (row 5 pin interface terminal)].
Applicable model: GT21. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 280kw.
SLD converter rated current: 610A.
Structure and function: Standard model .
Type: CA.
Substrate coating: have F940WGOT-LWD-E.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup
F940WGOT-LWD-E
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor F940WGOT-LWD-E.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor) F940WGOT-LWD-E.
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving. Cable length: 20m.
Connection between serial communication unit and GOT.
Connection between a computer link unit and a GOT.
Applicable models: GT16, GT15, GT11, HandyGOT, GT10, GT27, GT25, GT23,, GT21. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 3 linne /2 line type F940WGOT-LWD-E.
Sprinng clip terminal .
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the reeplacement module F940WGOT-LWD-E.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring.
F940WGOT-LWD-E Operation manual / Instructions / Catalog download link: