LK166
Home >> Price >> MITSUBISHI >> FA-LTBGTR4CBL20
Brand sort

MITSUBISHI FA-LTBGTR4CBL20

Country: JAPAN
Name: RS-485 terminal conversion cable
Price: 0
MITSUBISHI FA-LTBGTR4CBL20
Support for 10.4 inch /8.4 inch.
Applicable models: GT16, GT15. Analog input channel number: 4CH.
Available thermocouple: -.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s .
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range FA-LTBGTR4CBL20
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection mode: 18 point screw terminal FA-LTBGTR4CBL20.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control .
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control FA-LTBGTR4CBL20. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.
By cooperating with the time of arrival of a number of loops, the average temperature is controlled.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermal expansion. Can be divided into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy.
Peak current suppression function between modules
By the time staggered output transistor, suppressing peak current.
The power supply capacity of the equipment can be reduced by setting a larger channel and a smaller channel of the heater in the same set.
Can be divided into 5 groups. Input and output points: 480 points.
Input / output data points: 480 points.
Program capacity: 8k.
Basic command processing speed (LD command) s:1.25.
RAM memory capacity: 32K, power supply (DC24V).
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
Userr program storage cappacity: it is a measure of how much the user application can store the number of indicators FA-LTBGTR4CBL20.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words FA-LTBGTR4CBL20. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
FA-LTBGTR4CBL20 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=FA-LTBGTR4CBL20&select=5