DC5V DC current consumption: 0.23A.
Number of I/O modules can be installed: 8.
Program capacity: 8K step.
Input / output points: 256 points.
Number of input and output elements: 2048.
Power +8 tank bottom plate of the CPU.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function .
Can be set up to 32 characters of the file password HC-UP152B.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password
HC-UP152B
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights HC-UP152B.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.Input and output points: 30 points.
Power supply: AC100-240V.
Input points: 16 points.
Output points: 14 points.
Output form: relay output.
Power consumption: 21W.
Weight: 0.45KG.
Outline dimension: 100x90x75mm HC-UP152B.
A new application model .
FX3SA is a basic model on the basis of the basic performance of FX1S above the expansion of the expansion of the new model.
FX3SA is applicable to all kinds of fields of small scale equipment which need to simulate the quantity and function of MODBUS and Ethernet.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and communication function, etc.. Fiber optic cable / twisted pair cable.
Single bus.
Remote I/O station.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the systtem HC-UP152B.
MITSUBISHI PLC initiallization procedure . After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program arre:: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc HC-UP152B. .
HC-UP152B Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HC-UP152B&select=5