Function: high performance and low price in the middle end model.
Picture size: 12.1 inches.
Resolution: SVGA.
Display: TFT color.
Panel color: white.
Power type: DC24V.
The highest level model with multi touch and gesture features.
Specification rich, design at ease.
GT27 standard supports SD memory card and standard equipped with Ethernet, RS-232, RS-422/485, host/device USB interface HG-UR152.
Even in the log, script, alarm, soft component data transmission, such as high load processing period, but also to achieve smooth operation of the screen
HG-UR152
In addition, also supports video, animation playback, video input and RGB input and output, can use all the features of GOT2000 HG-UR152.
Can be programmed CPU and other procedures, parameters, such as data storage (backup) to the SD GOT memory card, USB memory .
When the programmable controller fails, batch write back (recovery) program.
1, the human body sensor
People will be able to automatically detect and display the picture.
2, USB interface: device USB (Mini-B USB)
Can connect to the computer to transfer data.
3, USB interface: host USB (USB-A)
GOT data can be transmitted through the USB memory or read log data and other data,
Can also be connected to the USB mouse, keyboard use HG-UR152.
4, the extension of the interface
Communication module and optional module can be installed.
5, Ethernet interface
Up to 4 different manufacturers can be connected to the FA machine.
6, RS-232 interface
Can connect all kinds of FA machine, bar code reader, serial printer.
7, RS-422/485 interface
Can be connected to a variety of FA machines, bar code reader.
8, SD memory card slot
Can save alarm and log data, such as a large number of data. Input: 2 channels.
500/200/100/10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
DC12/24V.
0.5A/ point.
2A common end.
40 pin connector. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 2.2KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power suppply, the starting current iis 6~7 times of the rated current, therefore, the impact on the mechanical and electrical HG-UR152.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rrated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load HG-UR152.
HG-UR152 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HG-UR152&select=5