Input type: AC.
Input points: 16 points.
Input voltage: AC100-120V.
Input current: 7mA.
Connection mode: terminal row.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations .
In the case of the computer for the PLC handheld programmer compile user program
A68DAI
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC A68DAI.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram . Its characteristics are basically consistent with the ladder diagram language A68DAI. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced. SI/QSI/H-PCF/ wide range H-PCF fiber optic cable.
Double loop.
PC inter network (management station / station) / remote I/O network (remote control station).
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also caan be carried out in second stteps A68DAI.
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system compooseed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram A68DAI.
So far the system''s hardware electrical circuit has been determined.
A68DAI Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A68DAI&select=5