MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AJ65BT-RPI-10B.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program
AJ65BT-RPI-10B MITSUBISHI universal AC servo amplifier MELSERVO-JE series AJ65BT-RPI-10B.
Rated output: 0.1kw.
Interface: General purpose.
Compatible motor: HG-KN13J-S100, HG-KN13BJ-S100.
MR-JE-A is equipped with a positioning function!
Be able to realize the positioning of the point set list and the way of the program.
At the same time, it also has a simple cam, encoder to follow, mark detection and other equipment can achieve high performance of the advanced functional group AJ65BT-RPI-10B.
Without positioning module, the controller can build a positioning system, which can simplify the system.
Command interface using DI/O and RS-422/RS-485 serial communication (maximum 32 axis),
Can simply set the positioning data through the Configurator2 MR. Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input AC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally opeen contact is closed,
Provide load current and voltage AJ65BT-RPI-10B.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnnected from the load AJ65BT-RPI-10B.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.