LK166
Home >> Price >> MITSUBISHI >> A8GT-J71QBR13
Brand sort

MITSUBISHI A8GT-J71QBR13

No PHOTO
Country: JAPAN
Name:
Price: 0
MITSUBISHI A8GT-J71QBR13
Max input / output points: 24 points.
Supply voltage: 100 - 240VAC.
Input points: 14 points.
Output points: 10 points.
Output type: transistor.
Power consumption (W): 32.
Weight (kg):0.5.
Size (WxHxD) mm:90x90x75.
Rich functionality.
FX series of products are rich in variety, users can be based on cost or application,
Choose the most suitable product A8GT-J71QBR13. Will find a suitable model for the user site A8GT-J71QBR13
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc..
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed.
In addition, you can also reduce the input output or special module A8GT-J71QBR13.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards. "Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Program capacity: 20K step.
Control mode: stored procedure repeated operation A8GT-J71QBR13.
Input / output points: 4096 points .
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carrieed out through the paraameters of the programming tool A8GT-J71QBR13.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurremment A8GT-J71QBR13.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "
A8GT-J71QBR13 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=A8GT-J71QBR13&select=5


...more relevant model market price >>>>