Power: 0.75kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor .
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table
AC100R4-25P
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate AC100R4-25P.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor .
The installation of thermal relay, to avoid overheating and burn the braking resistor. Cable length: 5.0m.
For QnA/ACPU/ motion controller CPU (A series, extended basis system) and the connection between A7GT-CNB.
Applicable models: GT16, GT15, GT11. Extending the device for FX1, PLC FX2, on PLC FX2N AC100R4-25P.
Need to use the conversion cable . Cable length: 10m.
For QnA/ACPU/ motion controller CPU (A Series) /FXCPU. Connection between (D-SUB25 pin connector) and GOT.
For the connection between FA-CNV*CBL and GOT.
Connector for serial communication unit and GOT.
For the connection between AJ65BT-G4-S3 and GOT.
Applicable models: GT16, GT15, GT11, HandyGOT, GT10, GT27, GT25, GT23,, GT21. Max input / output points: 64 points.
Power supply voltage: 24VDC.
Input points: 32 points.
Output points: 32 points.
Output type: Transistor (source).
Power consumption: 35W.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data viaa modem communications
Paassword protection, using a eight digit password to protect your program AC100R4-25P.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off tthe continuous scan time AC100R4-25P.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).