MITSUBISHI general purpose AC servo amplifier MR-J2 series.
Rated output: 0.1kw.
Interface: general purpose interface.
Voltage: single phase AC100V.
MITSUBISHI servo system in the MITSUBISHI servo amplifier is widely used,
It can not only be used in the high precision position control and speed control of the working machinery and general industrial machinery,
Can also be used in the field of speed control and tension control
A950GOT-SBD-M3
By installing a personal computer with a servo setting software, the parameters setting, trial run, state display, and gain adjustment are performed.
MITSUBISHI servo system MR-J2S column is developed on the basis of the servo MR-J2 series with a higher performance and more features of the MITSUBISHI servo system,
The control modes are position control, speed control and torque control, as well as the switching control mode among them A950GOT-SBD-M3. Application: installed on the surface of the panel or the use of L type mounting bracket,
So you can use a dedicated cable,
F9GT-HCAB-__M easily connect the hand-held GOT and RS-422 ports to connect / disconnect A950GOT-SBD-M3.
Attachment: L type mounting bracket .
Application Series: hand held GOT (RH type). Hardware implementation is mainly to control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced. Protective film for 5.7 inch screen.
Transparent (frame: white), 5.
Applicable model: GT11. Cable length: 3 meters.
For FXCPU (FX0, FX0S, FX0N, FX1S, FX1N, FX2N, FX2NC,) and GOT connection.
For FXCPU expansion board FX2N-422-B, FX1N-422-BD and GOT connection. Input points: 32 points.
Voltage: AC200 ~ 240V.
Current: 12mA.
Response time: 25ms.
32 points / a common end.
38 point terminal station.
CE certification.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the ooutput refresh A950GOT-SBD-M3.
The coontents of the component image register are changed with the change of the execution of the program .
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling A950GOT-SBD-M3.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
A950GOT-SBD-M3 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A950GOT-SBD-M3&select=5