Display: 16 characters x 4 lines.
Can monitor, change the value of software components.
Can also be simple to operate, change the value.
Equipped with a button operation can be used (operator certification function) and control through the PLC control function,
Can be used with the function expansion board .
Can be installed directly to the FX3GA, FX3G, FX3GE, no wiring AJ55TB32-4DT. Input points: 32 points.
Input voltage and current: 7mA DC12/24V
AJ55TB32-4DT
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC12V/24V.
OFF leakage current: 0.1mA.
Output response time: 2ms.
Output type: transistor output.
8 point /1 a public side AJ55TB32-4DT.
36 point terminal station .
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AJ55TB32-4DT.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signaal transmission device, brake signal and fan fault signal AJ55TB32-4DT.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee ssystem controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points AJ55TB32-4DT.
AJ55TB32-4DT Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=AJ55TB32-4DT&select=5