Input type: DC input, positive common end.
Input points: 8 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0 . 1A.
External connection: 3 line /2 line type AJ65SBTSF1-32T.
Sensor connection type.
Minimum size of industry
AJ65SBTSF1-32T
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Output points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
16 points / a common end AJ65SBTSF1-32T.
38 point terminal station .
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh AJ65SBTSF1-32T.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Undder the premise of meeeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ65SBTSF1-32T.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ65SBTSF1-32T.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
AJ65SBTSF1-32T Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=AJ65SBTSF1-32T&select=5