MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 7.5KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power
FR-A540-11K-CH A pack of 10.
Applicable models:
AJ65VBTS - - - type.
AJ65VBTCE - - - type.
AJ65VBTCU - - - type.
AJ65ABTP - - - type.
AJ65VBCU- - type. Total points: 10 points.
Input points: 6 points.
Output points: 4 points.
Voltage: AC220V.
Output type: relay.
Outline dimension: 60*75*90.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0 FR-A540-11K-CH.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment.5 slots.
To install the power supply.
For QnA/A series.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centtralized sampling FR-A540-11K-CH.
Cenntralized output mode .
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation FR-A540-11K-CH.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
FR-A540-11K-CH Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FR-A540-11K-CH&select=5