15 inches.
Surface treatment: transparent.
Protective film color: No.
USB protection cover parts: there is an opening.
Set number: 5.
Applicable model: GT27. MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.4kw.
Interface type: SSCNET type III fiber communication.
Special specification: suitable for linear servo motor FR-D720S-0.4K-CHT.
Power specification: single phase AC200V.
More advanced real-time automatic tuning by setting response values,
Including the position gain and the gain of speed, all the gain can be adjusted automatically
FR-D720S-0.4K-CHT
32 segment response level can be set.
Advanced vibration suppression control.
An optimal vibration control filter value is automatically set by the automatic tuning function to effectively suppress the vibration of the 100Hz frequency that occurs when the driving part stops FR-D720S-0.4K-CHT.
The automatic tuning function can effectively restrain the vibration of the end of the mechanical arm and reduce the residual vibration in the machine. 8 slots.
Power supply unit.
QnA series unit installation FR-D720S-0.4K-CHT.
High speed access.
CE logo fit.
I/O points is an important indicator of PLC .
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open ccontact is closed,
Provide load current and voltage FR-D720S-0.4K-CHT.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnnected from the load FR-D720S-0.4K-CHT.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
FR-D720S-0.4K-CHT Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FR-D720S-0.4K-CHT&select=5