Function: input / output module (internal service power supply).
Input / output points: 32 points
Input points: 16 points.
Output points: 16 points.
DC5V internal consumption current: 965mA.
DC24V internal consumption current: 250mA.
Input / output mode: DC input (drain / source) / transistor (source) .
In order to extend the input output of the device FX1S-30MR-001.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256
FX1S-30MR-001
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. "The length of the cable: 0.6 meters FX1S-30MR-001.
IQ-R MELSEC series of "inter module synchronization", refers to the module can be in accordance with the synchronization cycle between modules,
The function of the input and output time synchronization of the multiple input and output modules and the intelligent function modules of the synchronization object .
Using this function, the system and equipment can be controlled with high precision FX1S-30MR-001.
In addition, it is also available in the CC-LinkIE field network synchronous communication, so that the action time between the network nodes to maintain synchronization,
To avoid the error caused by the network transmission delay time, so as to build a stable system .
At the same time using these features, it can be easy to respond to the requirements of the high accuracy of the movement of the situation,
For example, the cutting and bending process of offset press, etc.. "For GT1030/GT1020 (used for operating system project data transfer) without power supply.
Applicable model: GT10. 3C-2V/5C-2V coaxial cable between double loop PC (control station / common station) / remote I/O network (remote master station).
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect.
Switch volume control is designed to,
AAccording to the currennt input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order FX1S-30MR-001.
So, sometimes also known as the order control.
And seqqueential control is divided into manual, semi-automatic or automatic FX1S-30MR-001.
And the control principle is decentralized, centralized and hybrid control three.
FX1S-30MR-001 Operation manual / Instructions / Catalog download link: