Use FX3S-CNV-ADP when connecting to the left of the basic unit of the FX3GA, FX3U, and FX3G.Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure FX2N-48MT-DSS.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic
FX2N-48MT-DSS
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file FX2N-48MT-DSS. "MITSUBISHI inverter series: FR-A846 .
Voltage level: three phase 400V.
Power: 3.7kw.
SLD converter rated current: 12.6A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product FX2N-48MT-DSS.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption .
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements.
The control of each machine can be done separately by the frequency converter, and the control of the dispersion is also carried out.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "DC input points: 2 points.
Input voltage and current: 7mA, DC24V.
Input response time: 10ms.
2 point /1 a public side.
Positive pole sharing.
Output points: 2 points.
Output voltage and current: DC24V.
Output response time: 2ms.
2 point /1 a public side.
Output form: transistor output, leakage type.
16 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc FX2N-48MT-DSS..
MITSUBIISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee prrogram FX2N-48MT-DSS.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
FX2N-48MT-DSS Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FX2N-48MT-DSS&select=5