Voltage input: DC-10~10V.
Current input: DC0~20mA.
Channel number: 4 channel analog output.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Resolution of 11 bit binary + symbol 1 (voltage), 10 bit binary (current) high precision analog output module .
Voltage output and current output of 4 channels can be carried out GT15-QBUS2.
Can be specified for each channel voltage or current output
GT15-QBUS2 Twisted pair cable.
Single bus.
Control unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system GT15-QBUS2.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc GT15-QBUS2. . PCI bus /PCI-X bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link basedd on reliable field bus teechnology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) GT15-QBUS2.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmisssion) communication separately, so as to ensure the timeliness of GT15-QBUS2.
Even if the information reaches saturation, it will not affect the link scan time.
GT15-QBUS2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=GT15-QBUS2&select=5