MITSUBISHI general purpose AC servo amplifier MR-J2 series.
Rated output: 0.6kw.
Interface: single axis positioning built-in type.
Voltage: single phase AC200V.
High response.
High precision positioning.
High level automatic tuning, can easily achieve gain settings.
Adopting adaptive vibration control and reducing vibration .
With a computer combination, using the software to achieve the best tuning
HF-KE23W1-S100
Pulse sequence input (position, speed control), analog input (speed, torque control) two purposes.
Simple operation.
The socket is arranged on the front panel, and is convenient to connect.
Using the socket, wiring easy.
Setting method and J2Super with interchangeable HF-KE23W1-S100. The length of the line: 2M .
IP level: IP65.
Relay type.
Bending life: high bending life.
Electric motor power supply cable (motor side), for HF-KP/HF-MP series (motor shaft with side extraction). Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
AnNCPU command processing time and ACPU compare to 10-20% high speed processing HF-KE23W1-S100.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenancee HF-KE23W1-S100. Input signal: thermmocouple type K or type J .
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Thermocouple type temperature sensor input module.
Thermocouple type (K type, J type) temperature sensor innpuut module HF-KE23W1-S100.
4 channels can be entered.
Unit can be set to Celsius or fahrenheit.
Resolution is K type 0.4 degree, J type 0.3 degree of high precision.
HF-KE23W1-S100 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HF-KE23W1-S100&select=5