Type: rectangle.
Screen mode: level 2.
Output: SPDT.
Power supply voltage: DC24V.
Contact type: small load operation (AC125V, 0.1A; DC30V, 0.1A).
Operation: instantaneous action (auto reset).
Color: yellow.
Operating under the color: green.
In the touch and the ability to protect than OMRON''s previous models have improved .
The micro volume design of 23mm is realized E5ER-TQT3DW-FLK AC100-240.
Micro design and unique combination of soft sensing
E5ER-TQT3DW-FLK AC100-240
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness E5ER-TQT3DW-FLK AC100-240.
From the front panel installation, more convenient . Input capacity: 32 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min. (between each in,
put terminal and the G terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the G terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC) E5ER-TQT3DW-FLK AC100-240.
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0 . 5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 32 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 230 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON coonnectors E5ER-TQT3DW-FLK AC100-240.
A common terminal is provided for,
each connector .
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswiitch and with tool software E5ER-TQT3DW-FLK AC100-240.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
E5ER-TQT3DW-FLK AC100-240 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5ER-TQT3DW-FLK AC100-240&select=5