Appearance: Round/Half-guard type A22-H.
Output: SPST-NO + SPST-NC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks E5EZ-C3MLD AC/DC24.
Finger protection mechanism on Switch Unit provided as a standard feature
E5EZ-C3MLD AC/DC24
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models) E5EZ-C3MLD AC/DC24.
IP65 (lighted models). Type: Welding / wire type, with left column .
Driving rod: swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1 E5EZ-C3MLD AC/DC24. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Transistor output: 2 points(sourcing).
Auxiliary output: None.
Functions: Heater burnout alarm, 2 (See note 3.); Event inputs, None.
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-chaannel gradient temmperature control for up to 2 groups E5EZ-C3MLD AC/DC24.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJJ1 Models E5EZ-C3MLD AC/DC24. ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise.
E5EZ-C3MLD AC/DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5EZ-C3MLD AC/DC24&select=5