A1ST60 analog timer module has 8 analog timers.
Each timer can be set between 0.1-600S,
Its accuracy plus or minus 2%.
Dial setting on the timing constant panel of the timer,
With a small screwdriver can be easily adjusted. Output type: transistor drain.
Output points: 16 points.
Load voltage: DC24.
Load current: 2A MITSUBISHI A1SJ71AT23BQ.
Connection mode: terminal row.
Common public end points: 8
A1SJ71AT23BQ
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI A1SJ71AT23BQ.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. I/O slots: 5 slots.
Could you install the power module.
Outline dimension: 315*130 MITSUBISHI A1SJ71AT23BQ.
There are two types of extended floor,
A power module can be inserted, and the other one is not.
The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate A1SJ71AT23BQ MITSUBISHI.
If the total demand is less than the power output, no additional power supply,
Then you can choose a more economical expansion board A1SJ71AT23BQ MITSUBISHI.
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection. Program memory capacity: 8k.
Input / output points: maximum 256 points.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh A1SJ71AT23BQ MITSUBISHI A1SJ71AT23BQ.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage MITSUBISHI A1SJ71AT23BQ.