LK166
Home >> Products >> MITSUBISHI >> A/QnA series PLC >> A/QnA series accessories >> A7GT-TK MITSUBISHI A7GT-TK

A7GT-TK MITSUBISHI A7GT-TK

Brand: MITSUBISHI
Name: parts
Model: A7GT-TK

2 channels.
10kpps.
Count input signal: DC5/12/24V.
External input: DC5/12/24V.
Output: DC12/24V, 0.5A.
38 point terminal station.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points MITSUBISHI A7GT-TK A7GT-TK
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book MITSUBISHI A7GT-TK. 8 slots.
Power supply unit.
QnAS series unit installation.
High speed access.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point MITSUBISHI A7GT-TK.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Providee load current and voltage A7GT-TK.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnected from the load A7GT-TK.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.


...More relevant models >>>>