LK166
Home >> Products >> MITSUBISHI >> CC-Link module >> Remote I/O module >> AJ65SBTB1-32T1 MITSUBISHI AJ65SBTB1-32T1

AJ65SBTB1-32T1 MITSUBISHI AJ65SBTB1-32T1

Brand: MITSUBISHI
Name: Transistor output module
Model: AJ65SBTB1-32T1
Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool.

Output type: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A.
External connection: 1 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole MITSUBISHI AJ65SBTB1-32T1.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition AJ65SBTB1-32T1
Can be installed along the 6 direction. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type MITSUBISHI AJ65SBTB1-32T1.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 line /2 line type.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Output type: transistor output, drain type MITSUBISHI AJ65SBTB1-32T1.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Input type: AC input.
Input points: 16 points.
Enter the response time: 20ms the following.
Rated input voltage / current: ACC100V/7mA AJ65SBTB1-32T1.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ65SBTB1-32T1.