Brand: OMRON
Name: Position Control Unit with MECHATROLINK-II interface
Model: CJ1W-NCF71
Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Unit with MECHATROLINK-II interface.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder programming.
Control mode: Position control,
speed control or torque control;
No. of axes: 16 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association.

Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V OMRON CJ1W-NCF71.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs CJ1W-NCF71
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F OMRON CJ1W-NCF71. S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) OMRON CJ1W-NCF71.
All inputs are isolated. Type: CJ1 Special I/O Unit.
Connected ID System: V680 Series; 2 Heads.
External power supply: --.
No. of unit numbers used: 2 unit number CJ1W-NCF71 OMRON.
Current consumption: 5V, 0.32A;
24V, 0.26A; External, --.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series CJ1W-NCF71 OMRON.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC.
Allows batch transfer of data up to 32 kbytes. A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs CJ1W-NCF71 OMRON.
Use Mixed I/O Units to easily ,
build space-saving systems. Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 32 inputs(High speed);
Input voltage and current: 24 VDC, 4.1 mA;
Commons, 16 points, 1 common; External connection,
MIL connector; No. of words allocated, 2 word.
Current cconsumption: 5V, 0 CJ1W-NCF71. 20A; 24V, --.
Standards: N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memoory in the CPU Unit OMRON CJ1W-NCF71.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.