LK166
Home >> Products >> OMRON >> Master slave station products >> CompoNet >> GRT1-OD4-1 | OMRON CompoNet Communications Unit GRT1-OD4-1

GRT1-OD4-1 | OMRON CompoNet Communications Unit GRT1-OD4-1

Brand: OMRON
Name: CompoNet Communications Unit
Model: GRT1-OD4-1
Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 outputs NPN.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON GRT1-OD4-1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction GRT1-OD4-1
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Internal I/O common: NPN.
I/O indicators: LED display (yellow) OMRON GRT1-OD4-1. 140 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors OMRON GRT1-OD4-1.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software GRT1-OD4-1 OMRON.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance GRT1-OD4-1 OMRON. Classification: For output.
Internal I/O circuit common: NPN (– common).
I/O points: 8 output points.
Connector Connection Models that.
Allows Easy Connection to Sensors and Output Devices.
Sensors with easy-to-wire connectors are easily,
attached or detached GRT1-OD4-1 OMRON.
Connects to 2-wire sensors.
Remote teaching of the Sensor Terminal is possible.
with the PLC by using output signals of the Sensor Terminal.
DIN track mounting and screw mounting are available. Classification: Analog input.
I/O points: 4 inputs (Resolution: 30, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler function.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function GRT1-OD4-1.
Two I/O points can be allocated to any two of the followingg values: analog,
input, peak/bottom, top, valley, or rate-of-change OMRON GRT1-OD4-1. Values without an,
allocated I/O point can be read with message communications.


...More relevant models >>>>