LK166
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-MD32BV-1 Board Terminals with MIL Connector OMRON DRT2-MD32BV-1

DRT2-MD32BV-1 Board Terminals with MIL Connector OMRON DRT2-MD32BV-1

Brand: OMRON
Name: Board Terminals with MIL Connector
Model: DRT2-MD32BV-1
Specifications: I/O, PNP (input: - common, output: + common), 16 inputs/16 outputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws.

I/O classification: Input.
Internal I/O circuit common: NPN (+ common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Module Type that Allows PCB Mounting.
Compact size at 60 x 16 x 35 (W x H x D).
Lineup now includes the 16-point input model and,
16-point output model. Specifications: Outputs; PNP (+ common);
16 points OMRON DRT2-MD32BV-1.
I/O connections: M3 screw terminals DRT2-MD32BV-1
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations OMRON DRT2-MD32BV-1.
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Name: System Units; End Unit *2.
Specifications: Necessary for,
terminating the Slice I/O Terminal.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON DRT2-MD32BV-1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error DRT2-MD32BV-1 OMRON. I/O classification: Temperature inputs DRT2-MD32BV-1 OMRON.
I/O points: 4 inputs.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
Input specification: Thermocouple.
Temperature Input Units for use with MULTIPLE I/O TERMINAL.
Four inputs.
Thermocouples and platinum resistance thermometer models,
are available.
Conversion time is only 250 ms for 4 inputs DRT2-MD32BV-1 OMRON.
The Configurator can be used to calibrate temperatures.
The circuit section can be removed, so rewiring isn’t,
required during maintenance.
DIN track mounting. Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost caan be reduced DRT2-MD32BV-1.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee OMRON DRT2-MD32BV-1.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.


...More relevant models >>>>