Ontology: basic.
Size: 48 x 96mm.
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 point (pulse voltage + pulse voltage / current).
Output (SUB) points: 2 points.
Event entry point: 6.
Serial communication: RS-485.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line.
The high speed sampling period is suitable for the operation of high speed response.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation.
1 digital controller can be multi point control / series control / proportion control.
Standard is equipped with a variety of computing functions.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program.
Thermocouple type: R.
Heat resistance: heat resistant.
Outside: all glass fiber outer wrapping stainless steel shielding layer.
Compensating wire length: 8 M.
A variety of high precision temperature sensor series.
On the basis of the previous M3 screw,
An additional rod like terminal corresponding to the reduced wiring working hours OMRON E5ER-QT3DB-FLK.
A temperature sensor is used as a thermal sensor for a thermostat
E5ER-QT3DB-FLK
According to the temperature, place, the surrounding environment to be measured.
Products with various shapes, shapes, lengths and terminals.
Size: DIN 1/8, 48 x 96 x 60mm.
Power supply voltage: AC100 ~ 240V.
Input type: Platinum resistance.
Alarm points: 1 points.
Control output: relay output.
Simple new temperature controller, easy to achieve temperature control OMRON E5ER-QT3DB-FLK.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- OMRON E5ER-QT3DB-FLK.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5ER-QT3DB-FLK OMRON. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy E5ER-QT3DB-FLK OMRON.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controllerr (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5ER-QT3DB-FLK OMRON E5ER-QT3DB-FLK.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON E5ER-QT3DB-FLK.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.