LK166
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TB161AC MITSUBISHI FA-TB161AC

FA-TB161AC MITSUBISHI FA-TB161AC

Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB161AC
Can be used as a screw relay terminal.

Transmission speed: 100Mbps/10Mbps.
MELSOFT connection.
SLMP cross letter (MC protocol).
Communication protocol support function.
E-mail function.
Web function.
Collect / change CPU module data from the other side of the device.
SLMP (MC protocol) communication
SLMP is a protocol that uses Ethernet to access SLMP devices from the other device MITSUBISHI FA-TB161AC.
If it is possible to follow the SLMP control procedures to send and receive messages to the device,
The communication can be carried out by SLMP FA-TB161AC MC can also support the previous agreement.
MELSOFT connection
Can be connected with the programming tool Works2 GX and other MELSOFT products.
In addition, through the use of communication tools to support the sale of (MX Component),
Regardless of the details of the protocol (how to send and receive procedures),
Can create a communication program on the upper side of the system MITSUBISHI FA-TB161AC.
It can easily connect to BACnet and MODBUS /TCP
Communication protocol support function
Through the Works2 GX communication protocol support function, can easily set the communication with the other equipment required for the agreement MITSUBISHI FA-TB161AC. DC5V internal consumption current: 0.08A.
Weight: 0.12kg.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcomputer,
Function is the interface of the programmable logic controller and the field control.
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
The programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module. AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, thee local power supply can be connected with the 4 wire type mixed use FA-TB161AC.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power suupply FA-TB161AC.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load.


...More relevant models >>>>