Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.
Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Output points: 16 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points) MITSUBISHI FA-TH16YRA20.
External wiring connection: 18 point terminal
FA-TH16YRA20
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch MITSUBISHI FA-TH16YRA20.
Communication protocol is a standard Modbus protocol or custom protocol. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.The connector is converted to a screw relay terminal.Differential output.
Axis of control: 1.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis MITSUBISHI FA-TH16YRA20.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action. Output points: 64 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two.
The switch input and output module is a device which can collect the inpuut / output of the switch signal,
Digital I/O modules are often called FA-TH16YRA20.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch FA-TH16YRA20.
Communication protocol is a standard Modbus protocol or custom protocol.