Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 150 A, 100 to 240 VAC.
Rated input voltage: 100 to 240 VAC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification).
Contact form: SPST-NO/SPST-NC.
Type: Models with Test Button and Built-in Operation Indicators.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load) OMRON G3PH-2150B AC100-240.
Models for AC Loads can switch 250 VAC, 15 A (resistive load)
G3PH-2150B AC100-240
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0.5 mm.).
Models available with operation indicators and built-in test buttons OMRON G3PH-2150B AC100-240.
RoHS compliant.
Standards: UL, IEC (TÜV certification). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 4 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) OMRON G3PH-2150B AC100-240.
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Input terminals: Compact slotted screw terminals (detachable) G3PH-2150B AC100-240 OMRON.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection) G3PH-2150B AC100-240 OMRON.
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters G3PH-2150B AC100-240 OMRON.
Detects the burnout of 3-phase heateers G3PH-2150B AC100-240.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) OMRON G3PH-2150B AC100-240.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.