Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 150 A, 100 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification).
Number of elements: 2.
Insulation method: Photocoupler.
Rated supply voltage: 100 to 240 VAC.
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VAC.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA OMRON G3PH-2150B DC5-24.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm)
G3PH-2150B DC5-24
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series. Insulation method: Phototriac.
Operation Display: Yes(green).
Output(SSR): AC.
Zero cross Function: NO.
Rated output Load: 2 A(at 100 to 240 VAC).
Rated input voltage (socket): 48 VAC/VDC, 100 VAC, 110 VAC, 200 VAC, 230 VAC OMRON G3PH-2150B DC5-24.
Applicable model: G3RV-SR700/500-A AC/DC48V,G3RV-SR700/500-A AC100V,
G3RV-SR700/500-A AC110V, G3RV-SR700/500-A AC200V, G3RV-SR700/500-A AC230V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel OMRON G3PH-2150B DC5-24.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Structure: Relays with PCB Terminals.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 1.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards G3PH-2150B DC5-24.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) G3PH-2150B DC5-24.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).