LK166
Home >> Products >> OMRON >> Relay >> General relay >> Built in power relay >> G7Z-4A OMRON G7Z-4A

G7Z-4A OMRON G7Z-4A

Brand: OMRON
Name: Power Relays
Model: G7Z-4A
Classification: Relay .
Structure: 4 poles.
Contact configuration: 4PST-NO.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications.

Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 75 A, 180 to 480 VAC.
Rated input voltage: 100 to 240 VAC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant OMRON G7Z-4A.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification) G7Z-4A Insulation mode: three end two-way switch coupler.
Zero trigger function: No.
Action indicator: there.
Applicable load of output: AC5 240V ~ DC5 1.0A ~ 100V.
Input rated voltage: DC24V.
With the same shape of the power FET MOS G2R relay AC/DC dual, can achieve 1A load switching performance OMRON G7Z-4A.
Can achieve AC240V or DC100V, 1A load switch.
Output open circuit leakage current: 10 A.
Input / output voltage resistance AC2500V.
Built in input resistance and over voltage absorbing circuit.
Can be carried out AC full wave rectifier load, half wave rectifier load switch.
Structure: Relays with PCB Terminals.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act OMRON G7Z-4A.
Number of poles: 1.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 100/110 VDC).
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC). Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The llineup also includes models that are compliant,
with the LR and VDE safety standards G7Z-4A.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) G7Z-4A.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).


...More relevant models >>>>