Type of input: DC leakage.
Input points: 32 points.
Input voltage: DC12/24.
Input current: 3/7mA.
Output type: transistor drain type.
Output points: 32 points.
Common public end points: 32.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and the standard electrical signal.
4 channel analog input module.
A1S64AD analog input module can accept the voltage or current signal,
The built-in microprocessor converts these signals to binary values,
For the control program to enjoy.
Signal can be instantaneous read, can also be programmed time / frequency average,
The offset and gain value can be set, and this component also includes the following performance:
4 input channels MITSUBISHI A1SH42
A1SH42
High resolution digital output.
Total accuracy plus or minus 1%. The 32 point pressure terminal line adapter to 0.33-0.75mm2 (AGW22-AGW18) European style Taiwan joint transform.Ethernet network module 10BASE-T / 10BASE5.Reader writer 1 channel connection, AnSCPU/QnASCPU.
PLC is the use of " sequential scanning, and constantly circulating " way to work MITSUBISHI A1SH42.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work MITSUBISHI A1SH42 A1SH42 MITSUBISHI.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan,, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process oof each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work A1SH42 MITSUBISHI A1SH42 MITSUBISHI MITSUBISHI A1SH42 A1SH42.