LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Protective equipment for equipment >> K2CM-Q4MA OMRON K2CM-Q4MA

K2CM-Q4MA OMRON K2CM-Q4MA

Brand: OMRON
Name: Motor Protective Relay
Model: K2CM-Q4MA
Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.

Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 300W.
Output voltage: 15V.
Output current: 22A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON K2CM-Q4MA.
Built in support for determining the abnormal causes of the new under voltage detection function K2CM-Q4MA
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage OMRON K2CM-Q4MA.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2 OMRON K2CM-Q4MA. (except for type 15/30W)
"
Power rating: 350 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 36 V VDC.
Output current: 9.7 A.
Built-in fan: Yes.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty K2CM-Q4MA.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved foor UL (all models) and CCC (15 to 150-W models) K2CM-Q4MA.
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.


...More relevant models >>>>