Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
an alarm signal.
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
work with both single-phase and three-phase heaters.
alarms due to variations in the supply voltage.
Type: Reverse wiring.
Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. The protection of the decentralized power supply to the power system,
The relay is smaller, and the protection unit is more enriched OMRON K2CU-F10A-FGS.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular
K2CU-F10A-FGS
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system OMRON K2CU-F10A-FGS.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal OMRON K2CU-F10A-FGS.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring.
Type: Standard type K2CU-F10A-FGS OMRON.
Shell: square body embedded type.
30 years of best-selling products new upgrade in the reservation,
Based on the basic functions to achieve a compact.
The installation dimensions of the surface type remain unchanged, the volume ratio of the volume ratio of the square body is reduced,
Half K2CU-F10A-FGS OMRON. (excluding AGD-U2)
Built in digital filter to reduce the impact of high frequency interference, to achieve a higher accuracy,
Leakage monitorinng K2CU-F10A-FGS.
The output point consists of 1c1a * monitoring circuit, an external signal based on contact,
Remote monitoring and alarm output of each monitoring circuit K2CU-F10A-FGS OMRON.
Cube embedded type also built-in buzzer. (exceptt AGD-U2) alarm output,
Optional external buzzer OMRON K2CU-F10A-FGS.
After the upgrade of all products can choose automatic reset, manual reset.
(AGD-N5, AGD-NY5, AGD-N52)