LK166
Home >> Products >> MITSUBISHI >> L series PLC >> I/O module >> LY41NT1P-CM MITSUBISHI Transistor output module (drain type)

LY41NT1P-CM MITSUBISHI Transistor output module (drain type)

Brand: MITSUBISHI
Name: Transistor output module (drain type)
Model: LY41NT1P-CM
Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol.

Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (drain).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V LY41NT1P-CM MITSUBISHI.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common LY41NT1P-CM
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points).
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged LY41NT1P-CM MITSUBISHI.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation LY41NT1P-CM MITSUBISHI.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability. Transmission speed: 100Mbps/10Mbps.
MELSOFT connection.
SLMP cross letter (MC protocol).
Communication protocol support function.
E-mail function.
Web function.
Collect / change CPU module data from the other side of the device.
SLMP (MC protocol) communication
SLMP is a protocol that uses Ethernet to access SLMP devices from the other device.
If it is possible to follow the SLMP control procedures to send and receive messages to the device,
The communication can be carried out by SLMP. MC can also support the previous agreement.
MELSOFT connection
Can be connected with the programming tool Works2 GX and other MELSOFT products.
In addition, through the use of communication tools to support the sale of (MX Component)),
Regardless of the details of the protocol (how to send and receive procedures),
Can create a communication program on the upper side of the system LY41NT1P-CM.
It can easily connect to BACnet and MODBUS /TCP
Communication protocol support functioon
Through the Works2 GX communication protocol support function, can easily set the communication with the other equipment required for the agreement LY41NT1P-CM.


...More relevant models >>>>