Output points: 8 points (independent of all points).
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Public side mode: no public side (all points of independent contact).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol.
"Universal output function: leakage type.
Program capacity: 60K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
CPU built-in functions can be easily set through programming tools MITSUBISHI LY18R2A-CM.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool
LY18R2A-CM
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated " MITSUBISHI LY18R2A-CM.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators MITSUBISHI LY18R2A-CM. "Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.The connector is converted to a screw relay terminal.Input and output (DC/ differential).
Input points: 12 points (DC5V/DC24V/ differential universal).
Pulse input speed: the highest pulse/s 8M (2MHz).
Output points: 8 points (DC5V ~ DC24V) 6 points (differential).
Pulse output speed: the highest pulse/s 8M (2MHz).
High speed and stable input / output response
The high speed response can be achieved without the CPU module''s operation and bus performance,
Stable input and output response through hardware processing.
LD40PD01 is equipped with an external input and output interface and FPGA,
Therefore, high speed control can be realized without the influence of the scanning time of the CPU module and the bus performance (the input and output response time of the s instruction is realized).
Can achieve stable input and output response (proceessing time of the deviation of the ns level) LY18R2A-CM.
Through the intuitive tools for FPGA settings.
In the FPGA design process can be omitted in the past must be designed to deal with (HDL description, logic synthesis and time verification),
Reeduce working hours LY18R2A-CM. After receiving the product can be used immediately to verify the use of special tools, can significantly shorten the design time.