LK166
Home >> Products >> OMRON >> Relay >> General relay >> Relay for control cabinet >> MKS1T-10 OMRON MKS1T-10

MKS1T-10 OMRON MKS1T-10

Brand: OMRON
Name: Power Relays
Model: MKS1T-10
Contact form: SPST-NO.
Type: Standard Models.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive load).
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0.5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification).

Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC 110V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel OMRON MKS1T-10.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals MKS1T-10
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires OMRON MKS1T-10.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Classification: Relay .
Structure: 4 poles.
Contact configuration: 4PST-NO.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC OMRON MKS1T-10.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications. Type: Standard.
Latching lever (Test switch): Yes.
Rated input voltage: DC, 21.
Applicable model: G2RV-SR701/501 DC24V, G2RV-SR701/501 AC/DC24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one polee 50 mA using Au-plated MKS1T-10.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed locatiion) MKS1T-10.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging.


...More relevant models >>>>