Name: Repeater Unit.
in the same way as for a Master Unit.
communications line.
Standards: CE, U, U1, L, N.
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
short-circuit detection function for protection.
Industry-standard e-CON connectors.
from I/O short circuits.
with flat cable and connectors.
essentially any application.
Specifications: I/O;
PNP (input: - common, output: + common);
Input: 8 points/Output: 8 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals OMRON CRS1-RPT01.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system
CRS1-RPT01
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier OMRON CRS1-RPT01. classification: Relay output.
I/O points: 8 points.
Rated voltage: 24 VDC.
Relay coil rating: 24 VDC.
Applicable relay: G6D-1A.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W x H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models OMRON CRS1-RPT01.
DIN track mounting and screw mounting are available. Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiaal cost can be reduced CRS1-RPT01.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CRS1-RPT01.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.