Name: Cycle Control Unit.
Isolation transformer: Yes.
Rated power supply voltage: 100 to 240 VAC.
Refer to Safety Precautions for All Power Controllers.
Used in Combination with the G3PA to.
Enable High-precision Temperature Contro.
Use cycle control to achieve power control with little noise.
three-phase loads.
external adjuster, or DC signals from 4 to 20 mA.
Streamline design. Both DIN track mounting and screw,
mounting possible.
Use linking terminals for close mounting of the G3PA.
Built-in isolation transformer.
Power supply range: 100 to 240 V.
Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 15 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase OMRON G32A-EA AC100-240.
Heaters Reduced Installation Work.
with DIN Track Mounting
G32A-EA AC100-240
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) OMRON G32A-EA AC100-240.
Conforms to UL, CSA, and EN standards (TÜV certification). Type: With built-in diode.
Contact form: DPDT.
Cased: Plug-in (octal pins)terminals.
Stable Contact Reliability and Long Life.
Easy to mount, wire, and use.
A large selection of models including various contact forms,
DC-switching models, and open models.
Mechanical life: 5,000,000 operations; electrical life,
(under rated load): 500,000 operations OMRON G32A-EA AC100-240.
Models also available with built-in diodes and for use as,
auxiliary power relays. Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle controol G32A-EA AC100-240.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G32A-EA AC100-240.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.